Orlando Spray Foam Insulation InspectionIt’s time to reduce your carbon footprint and a great way to begin the process is to re-insulate your home.  You’ve been told that it’s a simple process of adding new spray polyurethane foam insulation in the attic.  You’ve been told that you can save up to 20% on your next energy bill.  You’ve also been told that you’re currently losing as much as 40% of your homes energy efficiency due to air infiltration.

Spray foam offers a solution: it performs as both insulation and an air sealant, or air barrier, closing those nooks and crannies that let air escape and add dollars to monthly energy bills. You’ve double checked what your SPF salesman has told you about the energy savings and found that the U.S. Environmental Protection Agency’s (EPA) Energy Star program estimates that by adding insulation and sealing air leaks you can save up to 20% on your monthly energy bills.

You’ve also found that the U.S. Department of Energy estimates that 56% of the energy used in a home goes to heating and cooling. Your home’s heating, ventilating, and air conditioning (HVAC) system has a big effect on your utility bills and your energy consumption because it has to work hard to keep up with all that air leakage.

You’ve done your homework and you’ve decided to move forward with your purchase and application of spray polyurethane foam insulation in your home’s attic.  You’re excited about increasing your “R” value and saving those energy bucks but still just a bit concerned about all those potential indoor air quality IAQ issues that you have been reading about while researching the energy savings of SPF.

Spray foam insulation can help reduce the workload on your HVAC system thanks to its high R-value and effectiveness. In fact, with spray foam, HVAC sizing can be reduced as much as 35% without the loss of efficiency and comfort.

With some luck you’ve read my previous articles and have asked some very critical questions prior to your decision.  Remember, there are differences between spray polyurethane foam insulation and blown or batt insulation that go well beyond the R value and energy savings.

All insulation products aren’t created equally and some insulation products provide much more than just R Value.  When you install spray polyurethane foam SPF insulation, you change the way your home performs.  You’re reducing your homes air leakage or air infiltration.  Great stuff right?  Well, yes and no.  Yes for energy efficiency - less is more analogy is a good thing; however, when it comes to your indoor air quality, IAQ, less is definitely not more and absolutely not better.

Your home’s air leakage or air infiltration rate is the source of the home’s air change rate ACH.  When you seal up your home you may also be substantially reducing your home’s ACH.  When you insulate with SPF you’re not just improving your home’s R-value, you’re changing the way your home achieves the ACH necessary to maintain good indoor air quality.

Today, we have very specific guidance documents that help both the consumer and the applicator better understand the difference between a traditionally ventilated attic and a SPF unvented attic.

Guidance on Best Practices for the Installation of Spray Polyurethane Foam established by the Spray Foam Coalition of the American Chemistry Council, ACC, Center for the Polyurethanes Industry states that the contractor and the homeowner should be aware that retrofitting an existing attic by employing an unvented attic assembly technique can result in the existing HVAC system becoming “oversized” in relation to the new demand.

This situation is of special concern in the southern and coastal climate zones where the HVAC also serves to reduce or otherwise manage moisture levels of buildings in order to improve comfort and prevent moisture related problems, such as mold and mildew. If an existing HVAC becomes “oversized” due to the increased thermal efficiency of the unvented attic assembly, the HVAC system may begin to short cycle, or to quickly turn on and off, as it works to manage temperature. This short cycling of the HVAC system may have negative impacts on the comfort and efficiency of the building and possibly on the lifespan of the system.

The guidance document recommends that the application contractor involve an HVAC consultant to adapt the system to the new, more efficient building envelope associated with the spray foam retrofit.

By far, the majority of the complaints I respond to are a direct result of inadequate ventilation and no method or design consideration for the now semi-conditioned attic.

The Spray Polyurethane Foam Alliance, SPFA Builder’s Reference Handbook, list the HVAC and Ventilation as one of their initial Design Considerations.  

The SPFA Builder’s Reference Handbook recommends an Initial Evaluation “Test In” and a Final Evaluation “Test Out”
Initial Evaluation (Test-In)

The Initial Evaluation (Test-In) is a complete evaluation of the existing home before the installation of the SPF insulation.

Items to address and checked during the Test In can include:
•  Air Leakage Testing, to establish the air infiltration rate
•  Existing Attic Insulation (type location and recommended method of removal)
•  Inspection of Related Systems (e.g. HVAC, kitchen, and bathroom exhaust ventilation)
•  Combustion Appliances (reduced ACH and make-up air may be an issue as well as ventilation)
•  Energy Savings Estimate by independent trained professionals (BPI and RESNET)

The Test In air leakage testing is performed using a blower door to evaluate the home’s air leakage and natural ventilation before SPF application.  This is then used as a baseline for quality checks and energy savings estimates.  This test for existing homes should be performed before and after SPF installation.

This initial air leakage or air infiltration rate is the source of the home’s air change rate ACH with a traditionally ventilated attic.  The air infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h. The air exchange rate is also known as air changes per hour (ACHs).  ACH can be calculated by multiplying the building's CFM by 60, and then dividing by the building volume. (CFM x 60)/volume.

The American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) has had a residential ventilation standard since 2003, ASHRAE 62.2.  The ASHRAE 62.2 minimum ventilation rate formula was set at 7.5 cfm per person plus 1 cfm per 100 square feet.

The standard assumes that the number of occupants in a home equals the number of bedrooms plus one. The ASHRAE 62.2 asserted that the formula used to determine the minimum airflow rate of ventilation equipment was based on the assumption that all homes deserve an “air infiltration credit” of 2 cfm per 100 square feet.  This was the assumption that the homes in and before 2003 had a good amount of air infiltration.  The homes built today with or without the use of SPF insulation are much tighter and have a substantially reduced air infiltration rate.

So while your home’s recommended minimum ventilation rate remained unchanged for many years, ASHRAE has recognized the tighter construction of today’s homes and 10 years after the initial ASHRAE 6.2, there are new changes to the 2013 version of ASHRAE 62.2.  Under the new formula, newer tightly built homes will need to be ventilated at a much higher rate, namely 7.5 cfm per person plus 3 cfm per 100 square feet. This means that for a tightly built 2,400-square-foot home with 3 bedrooms, the minimum airflow rate of the ventilation equipment has jumped 89%, from 54 cfm to 102 cfm.  Long story short, the 2013 version of ASHRAE 62.2 has eliminated the air infiltration credit on new tightly built homes.

Once you apply the Spray Polyurethane Foam Insulation in your attic, your home’s air leakage or air infiltration rate will be greatly reduced.  This is why the SPFA Builder’s Reference Handbook recommends the Test In and Test Out with the use of a blower door to establish your homes air leakage or air infiltration rate.  The Test Out your air leakage or air infiltration rate will determine the amount of outdoor air your home will require to meet the minimum ventilation rate or the ACH of 7.5 cfm per person plus 3 cfm per 100 square feet.

Final Evaluation (Test-Out)

The Final Evaluation (Test-Out) is also a complete evaluation of the existing home after the installation of the SPF insulation.

Complete Evaluation After Installation can include:
•  Air Leakage Testing
•  Repeat blower door test after installation
•  Inspect for air leaks in foam and repair
•  Confirm energy savings projections

The Test Out air leakage testing is once again performed using a blower door to evaluate air leakage and natural ventilation after the spray polyurethane foam insulation application.  This test is then used as the actual as-built air leak and natural ventilation rate.  The blower door test will provide you with your ACH by measuring your home’s actual amount of air leakage.  With this information, you will now know how much additional outdoor air the home will require to meet the minimum ventilation rate.

Among other issues the Test Out as compared to the Test In is the potential need for HVAC Modifications.  The SPFA Builder’s Reference Handbook states that “If application of SPF renders the home to be insufficiently ventilated, work with HVAC contractor to add mechanical ventilation or HRV/ERV.

SPFA Builder’s Reference Handbook clearly informs the application contractor that creating an unvented attic (UVA) with SPF can alter a home by:
•  Reduce uncontrolled air leakage
•  Lower HVAC energy costs
•  Improved insulation performance
•  HVAC system inside the building envelope operates under more moderate temperatures

Most HVAC systems are oversized to account for excess air leakage which directly affects the energy efficiency as well as effectiveness dehumidification.  The application of spray polyurethane foam insulation may actually allow for the downsize of the HVAC system for better performance.

Adjustments or downsizing of HVAC system may be needed to:
•  Achieve Good IAQ
•  Meet the minimum mechanical ventilation rate via outdoor air supply and a dehumidifier or ERV/HRV
•  Avoid short-cycling of AC system for proper dehumidification
•  Supplemental humidification/dehumidification to control relative humidity

To definitively establish the needs for any home once SPF has been installed and the traditional vented attic has been changed to an unvented attic, the use of a blower door must be used to establish the home’s natural ventilation rate and the homes mechanical system requirements must be properly calculated using a Manual J for load calculation, a Manual S for equipment selection, and a Manual D for proper duct design.

Without the known natural ventilation rate, you can only guess at the amount of outdoor air necessary to meet the minimum ventilation rate.  That is if you have even taken the ACH into consideration and added the necessary outdoor air supply.  With the known natural ventilation rate and the new R values, the homes HAVC can be correctly calculated and designed.

You would think knowing the impact of changing from a vented attic to a spray polyurethane foam insulated unvented attic that most home owners are performing the Test In and Test Out procedures.  In actuality, less than 10% of the homes I assess have had any form of Test In or Test Out performance evaluation.  It’s rare that the issue of ventilation or the home’s HVAC system is discussed at all.
Remember earlier in this article we discussed the Guidance on Best Practices for the Installation of Spray Polyurethane Foam states that the contractor and the homeowner should be aware that retrofitting an existing attic by employing an unvented attic assembly technique can result in the existing HVAC system becoming “oversized” in relation to the new demand.

The guidance document also recommends that the application contractor involve an HVAC consultant to adapt the system to the new, more efficient building envelope associated with the spray foam retrofit.

The Guidance goes on to further address the home’s ventilation system:

Important note about air Handlers
If a ventilation system that uses the HVAC air handler fan to provide the needed outdoor air (as is the case in many supply ventilation strategies) is used, it is imperative to ensure that the air handler fan operates often enough to provide sufficient fresh air. During periods of mild weather, or at night in the summer, the air handler fan may not be called on to run for several hours, so the house would get no outdoor air during these times. To address this, control units are now available that will ensure the house always gets the needed ventilation. If the air handler does not operate enough for sufficient ventilation, the monitors will call for the fan to operate and provide sufficient fresh air.

Typically, most homes need for the fan to run for between 10 and 20 minutes each hour to meet the home’s ventilation needs. An example of this type of fan control unit is the Aprilaire 8100.

The introduction of outdoor air not only affects the temperature in the house, it also impacts the humidity in the house. Here in Florida, the humidity can be a critical factor that is often overlooked. Our hot humid southern Florida outdoor air supply will require mechanical dehumidification. It’s critical to include ventilation air in the ACCA Manual J, Eighth Edition (J8) HVAC sizing calculations.

Mechanical System Calculations
Residential Mechanical System guidelines include:

•  Manual J:* Load Calculation
•  Manual S: Equip. Selection
•  Manual D:* Duct Design

Manual J
Manual J is the name for a specific protocol (often called “Heat Load Calculation” or “Cooling Load Calculation“) used to determine how much heating/cooling a home needs to stay cool and dry in the summer and warm in the winter. This load calculation process was developed by engineers in the heating and air conditioning industry and has been used for decades to accurately size heating and air-conditioning equipment. After completing this load calculation process, one can choose a properly sized piece of machinery to satisfy the load.

A Manual-J load calculation report provides three main pieces of information regarding heating and cooling load:
Heating Load: This is how much heat your house will require on the almost-coldest day of the year, in the middle of the night (when there’s no help from the sun). This is the number, or load, used to select a piece of heating equipment.

Sensible Cooling Load: This is the amount of sensible heat (the type you measure with a thermometer) that your system should be able to remove on the almost-warmest day of the year, during the daytime (when the sun is heating up the building). This is used, IN COMBINATION WITH the next load-type, to select the cooling equipment.

Latent Cooling Load: This load describes how much moisture your system should be able to remove under “worst-case” conditions. Worst-case for latent loads are typically when it’s hot and wet outside (daytime in the summer).

These three loads are used to select a piece of machinery that fits the loads (heat losses or gains) of your home. When selecting air conditioners or heat pumps, the two cooling loads should be used. And, the selected piece of machinery should be able to supply the proper amount of BOTH latent and sensible cooling, and be less that 15% over-sized, based on the Manual-J load calculation. This will ensure your system is capable of proper dehumidification (assuming the distribution system is performing properly).

Manual S
Proper equipment selection important and achieving occupant satisfaction is the principal goal of any HVAC design. Occupant satisfaction is maximized when the heating and cooling equipment are the correct type and size to meet the capacity requirements from the Manual J load calculation.  For residential equipment selections, ACCA’s Manual S, is the only procedure recognized by the American National Standards Institute (ANSI). If the Manual J load calculation is done then the next step is to select the equipment that will deliver the necessary heating and cooling.

Undersized equipment will not meet the customer’s comfort requirements at the design specifications.

Oversized equipment will create other problems:
•  Degraded humidity control in the summer.
•  Occupants may suffer the effects of an increased potential for mold growth. These same conditions also may contribute to asthma and other respiratory conditions.
•  The temperature may feel right at the thermostat but the temperature in other rooms will suffer from the oversized equipment going through short operation cycles. Short cycles can cause temperature swings as the equipment over-conditions, stops, then over-conditions, etc…
•  Hot and cold spots between rooms because the thermostat is satisfied but the room is not.
•  Oversized equipment generally requires larger ducts, increased electrical circuit sizing and larger refrigeration tubing. These cause higher installed costs and increased operating expenses.
•  The equipment starts and stops more frequently, this causes excessive wear and can increase maintenance costs more service calls.
In these unfavorable conditions occupants will experience discomfort and dissatisfaction.

Manual D
The next step is the duct design.  For residential air duct designs ACCA’s Manual D is the procedure recognized by the American National Standards Institute (ANSI) and specifically required by residential building codes. Air is the first word in air conditioning. If the network of ducts carrying the air is not properly designed then the health and safety of the occupant are at risk, the equipment could fail more quickly, the energy costs could rise, and occupant comfort might be sacrificed.

In order for home owners to be comfortable, a duct system must be designed to carry the right amount of air, at the right speed, into the right room. If the ducts are the wrong size then the wrong amount of air will enter the room and may cause:
•  The room to be too warm or too cool
•  The air to be too drafty and disturb people while they sleep, eat, read, etc...
•  The air to be too noisy and drown out conversations, TV or radio programs, etc...
•  The air to be too slow – the conditioned air will not circulate or mix well in the room.
•  The fan to work harder, possibly fail sooner, and use more energy to move air
•  The furnace or air conditioner safety devices to stop equipment operation
•  Pressure differentials that may increase energy costs by pushing out conditioned air or drawing in unwanted air

The design and installation of your homes HVAC system with your new spray polyurethane foam insulation SPF insulated home.
The issue of home performance and ventilation must become a more critical aspect of the spray polyurethane foam insulation SPF retro-fit sales pitch.  Understanding the performance changes within a home by altering the attic from traditionally vented to spray polyurethane foam insulation SPF unvented would eliminate a large portion of the SPF occupant odor complaints.

You might be thinking that the new construction homes have it made right?  Well, not so much.  Believe it or not, many new homes are designed with no alterations to the home’s ventilation system in the area of the ventilation rate (outdoor air) and the semi-conditioned attic space.  Many new homes actually have a reduction in size of the HVAC equipment as discussed earlier.  There is absolutely nothing wrong with altering the home’s HVAC system to accommodate the new tighter design and improved R-value; however, there is a huge issue with the builder not taking into consideration the reduced air infiltration, ventilation rate, or air changes per hour ACH. Carbon dioxide, CO2 emissions from the new building material and the dilution of the volatile organic compounds, VOC’s due to the homes ACH.

In a tightly sealed spray polyurethane foam insulation SPF home, the VOC’s accumulate in the attic. The VOC laden warm indoor air rises to the attic as the living space is cooled.  Over time, this accumulation, if not properly diluted, can actually make its way down into the living space from the attic.  The necessary outdoor air supply needs to properly dilute the new construction VOC’s.  It’s the accumulation of these volatile organic compounds, VOC’s that is often directly associated with the SPF.  Fortunately, we have well established studies of new construction homes with traditionally vented attics and no SPF insulation.  These SPF free new construction VOC’s can then be compared to the samples collected from new construction homes with SPF insulation and unvented attics.  If the SPF is bad, the VOC signature will be different than that of a traditional home with no SPF. It seems simple right?  Well, there remain those that sample heavy and look at nothing when it comes to SPF insulation and simply point to the SPF insulation without addressing the home as a whole.

When assessing the condition of any home with SPF insulation and occupant complaint, the home must be inspected as a whole.  The inspection must include the design and performance of the home.  For these new construction inspections there are two specific areas of concern other than the physical inspection of the installed SPF.  First, is the home’s ventilation rate.  We need to know what the home’s ACH is and we need to know if we are at least attaining the minimum ACH recommended by the ASHRAE 62.2.  Second, is the ventilation design of the semi-conditioned attic space.  How is the homes semi-conditioned attic being addressed and ventilated?

These are the primary factors in a home’s ability to properly condition and maintain the indoor environment.

No air circulation in the unvented attic will lead to an elevation of heat, humidity, and VOC’s.  There must be a specific method of circulating air through the semi-conditioned attic space.  If you don’t take ownership of this space in your ventilation design and you assume that the space will be passively semi-conditioned, be prepared to meet me on site at a future date.  We’re not talking about fully conditioning the space by installing supply and return vents in the attic. You need to move air through the semi-conditioned attic.  If you don’t, the attic simply isn’t semi-conditioned.  It’s unconditioned unvented attic space that will soon be a source of odor and occupant complaint.

So you may be asking just how we establish the new construction ventilation rate and method of semi-conditioning the attic.

Final Evaluation (Test-Out)
The Final Evaluation (Test-Out) is also a complete evaluation of the new-construction home after the installation of the SPF insulation.

Complete Evaluation After Installation can include:
•  Air Leakage Testing
•  Blower door test after installation
•  Inspect for air leaks in foam and repair
•  Confirm energy savings projections

The Test Out air leakage testing is performed on the new construction home by using a blower door to evaluate air leakage and ventilation with the unvented attic insulated with spray polyurethane foam.  This test is then used as the actual as-built air leak and natural ventilation rate.  This test and amount of measured actual natural ventilation will tell us exactly how much additional outdoor air is necessary to meet the minimum ventilation rate.  The SPFA Builder’s Reference Handbook states that “If application of SPF renders the home to be insufficiently ventilated, work with HVAC contractor to add mechanical ventilation or HRV/ERV.”

You hear the real estate professionals repeating it’s all about the “Location, Location, Location.”  Well the indoor air quality guy says it’s all about the “Ventilation, Ventilation, Ventilation!”

So at the risk of being overly redundant, ventilation cannot be stressed enough in a home with spray polyurethane foam insulation and an unvented attic.

Any home with spray polyurethane foam insulation and an unvented attic must have a method of semi-conditioning the unvented attic to provide the necessary air circulation to prevent the accumulation of heat, humidity, and VOC’s.  That can’t be found in expensive air sampling for VOC’s.

 Any home with spray polyurethane foam insulation and an unvented attic must establish the necessary minimum ventilation rate necessary to prevent occupant complaint while providing good indoor air quality.  That can’t be found in expensive air sampling for VOC’s.

However, both can be identified by measuring the homes performance and the use of a blower door test.  And both can be improved and/or corrected once the actual performance testing has been completed.

So reduce your carbon footprint and save those energy bucks.  Spray polyurethane foam insulation is a great home improvement method of saving energy.  Just remember one thing; if your home is ventilated the same way after the installation of spray polyurethane foam insulation you haven’t finished the home improvement process.

Ventilation, ventilation, ventilation……………..

To learn more about Mr. Lapotaire or Indoor Air Quality Solutions & Microshield Environmental Services, LLC, please visit www.FloridaIAQ.com, email info@FloridaIAQ.com or call (407) 383-9459.

About Indoor Air Quality Solutions & Microshield Environmental Services, LLC

Since 2001, Florida residents have turned to the indoor environmental experts at Indoor Air Quality Solutions & Microshield Environmental Services, LLC.  The family owned and operated companies, based in the Orlando area, offer a comprehensive approach to identifying and correcting comfort and indoor air quality problems.  Their expert staff utilizes the latest technologies and industry recognized standards to identify and resolve indoor environmental issues.

John P. Lapotaire, CIEC
•Certified Indoor Environmental Consultant
•Indoor Air Quality Solutions, IAQS
•Microshield Environmental Services, LLC
•www.Microshield-ES.com  www.CFL-IAQ.com
•www.FloridaIAQ.com
•http://www.microshield-es.com/moldinspectiontesting.html
•http://www.orlandomoldinspection.us/
•http://www.microshield-es.com/nuisanceodor.html
•http://www.floridaiaq.com/moldremediationprotocol.html
•http://www.floridaiaq.com/moldclearancetesting.html

#IAQS


Add a Comment

(Enter the numbers shown in the above image)


Follow jlapotaire on Twitter


Review microshield-es.com on alexa.com
   

[Valid RSS]
Add this Content to Your Site
   


Latest Top (12) News


EPISODE511: Chuck Violand, Ross Riek, Owen Boak and The Restoration Global Watchdog!
This past June RIA held its first International restoration conference and trade show on Australia’s beautiful Sunshine Coast. The event which will be an annual offering in the region was organized and delivered by RIA’s Australasian Council. The local RIA conference planning committee collaborated with the Australian IAQA chapter leadership and featured several education sessions by local leading IAQ experts. Mold seemed to be a hot topic at the conference with several labs exhibiting at the trade show! The event was also attended by IICRC leadership and several other regional dignitaries from related segments of the cleaning, restoration and remediation industries.

Thu, 03 Jan 2019 13:00:00 -0800


EPISODE497 - Radio Joe and the Z-man – Using Building Science & EPA’s Moisture Control Guide to Improve Indoor Air!
Today Radio Joe and the Z-man will be discussing how to solve indoor environmental quality problems by using building science fundamentals and the “EPA Moisture Control Guide”. To get at the root of IEQ problems you must understand buildings and building science. Today we will discuss some great information from people like Joe Lstiburek, Terry Brennan, Bill Rose, Mike McGuinness and Lew Harriman. We start with an overview of building science concepts that will help you solve problems. Our foundation will be the 4 P’s (people, pollutant, pathway, pressurization). From there we will go into how to use the wealth of information in the EPA “Moisture Control Guide” and then go through some case studies. On a future show we will get into how to include the information in your reports

Thu, 11 Oct 2018 09:00:00 -0700


EPISODE512: FLASHBACK FRIDAY – Paul Francisco – University of Illinois at Urbana-Champaign – Ventilation and IAQ – EPISODE 448 (Air Date: 2-17-2017)
Paul Francisco runs The Indoor Climate Research and Training Group at The Applied Research Institute of the University of Illinois, Urbana-Champaign. He does both research and training on issues related to home performance, and his research focuses on indoor air quality, energy efficiency and emphasizing field measurements. His training focuses on teaching practitioners building diagnostics and Health and Safety. He’s also been a trainer in that area in the home weatherization assistance program. He’s done extensive work on curriculum development for weatherization workers and also research on energy efficiency and indoor air quality in existing homes. He is also the current Chair of the ASHRAE 62.2 Ventilation and Acceptable Indoor Quality in Residential Buildings. He’s got his Bachelors degree from University of Delaware and a Masters in Mechanical Engineering from the University of Washington

Fri, 03 Aug 2018 13:00:00 -0700


EPISODE512: FLASHBACK FRIDAY – Paul Francisco – University of Illinois at Urbana-Champaign – Ventilation and IAQ – EPISODE 448 (Air Date: 2-17-2017)
Paul Francisco runs The Indoor Climate Research and Training Group at The Applied Research Institute of the University of Illinois, Urbana-Champaign. He does both research and training on issues related to home performance, and his research focuses on indoor air quality, energy efficiency and emphasizing field measurements. His training focuses on teaching practitioners building diagnostics and Health and Safety. He’s also been a trainer in that area in the home weatherization assistance program. He’s done extensive work on curriculum development for weatherization workers and also research on energy efficiency and indoor air quality in existing homes. He is also the current Chair of the ASHRAE 62.2 Ventilation and Acceptable Indoor Quality in Residential Buildings. He’s got his Bachelors degree from University of Delaware and a Masters in Mechanical Engineering from the University of Washington

Fri, 03 Aug 2018 13:00:00 -0700


EPISODE508: HOMEChem Open House – House Observations of Microbial and Environmental Chemistry
This week on IAQradio+ will be broadcasting live from the Open House event for the HOMEChem study at the University of Texas Austin’s, J.J. Pickle Research Campus. The HOMEChem experiment (House Observations of Microbial and Environmental Chemistry) incorporates state-of-the-art measurements performed by over 20 investigators and their teams from the fields of chemistry, microbiology, and engineering. This experiment engages far more institutions and disciplines than ever applied to the study of a home. This research study is sponsored by the Alfred P. Sloan Foundation Chemistry of Indoor Environments Program and it will take place this summer at the University of Texas at Austin’s UTest House. Our guests for this special show are Marina Vance (HOMEChem Co-PIs / organizer) Delphine Farmer (HOMEChem Co-PIs / organizer) Atila Novoselac (HOMEChem host, specialist on the UTest house) Rich Corsi (HOMEChem host, indoor air specialist) Dr. Richard L. Corsi is the Joe J. King Chair in Engineering #2 in the Department of Civil, Architectural and Environmental Engineering (CAEE) at The University of Texas at Austin (UT Austin). He has served on the faculty of CAEE at UT Austin for nearly 25 years, after starting his career in the School of Engineering at the University of Guelph in Ontario, Canada. Dr. Corsi is highly regarded as an educator. He has received numerous teaching awards, and in 2015 was inducted into the Academy of Distinguished Teachers, an honor held for the top 5% of teachers across UT Austin. He also received a Regents’ Outstanding Teaching Award for the entire UT system in 2016. Dr. Corsi’s research focuses on sources, physics and chemistry of indoor air pollution, particularly as related to pollutant interactions with indoor materials and innovative strategies for using such interactions to reduce human exposure to air pollution of both outdoor and indoor origin. He has served as principal investigator on over 70 projects, as major advisor to over 50 undergraduate and 70 graduate students, and as co-author on over 300 journal/conference papers, reports, and book chapters. His work has been featured in National Geographic, The Economist, Business Week, National Wildlife, Prevention, Men’s Health, National Public Radio’s Science Friday, Science Studio, the Academic Minute, the Canadian television series The Nature of Things, and more. Delphine Farmer, PhD Dr. Delphine Farmer is an Associate Professor in the Department of Chemistry at Colorado State

Fri, 22 Jun 2018 13:30:00 -0700


EPISODE508: HOMEChem Open House – House Observations of Microbial and Environmental Chemistry
This week on IAQradio+ will be broadcasting live from the Open House event for the HOMEChem study at the University of Texas Austin’s, J.J. Pickle Research Campus. The HOMEChem experiment (House Observations of Microbial and Environmental Chemistry) incorporates state-of-the-art measurements performed by over 20 investigators and their teams from the fields of chemistry, microbiology, and engineering. This experiment engages far more institutions and disciplines than ever applied to the study of a home. This research study is sponsored by the Alfred P. Sloan Foundation Chemistry of Indoor Environments Program and it will take place this summer at the University of Texas at Austin’s UTest House. Our guests for this special show are Marina Vance (HOMEChem Co-PIs / organizer) Delphine Farmer (HOMEChem Co-PIs / organizer) Atila Novoselac (HOMEChem host, specialist on the UTest house) Rich Corsi (HOMEChem host, indoor air specialist) Dr. Richard L. Corsi is the Joe J. King Chair in Engineering #2 in the Department of Civil, Architectural and Environmental Engineering (CAEE) at The University of Texas at Austin (UT Austin). He has served on the faculty of CAEE at UT Austin for nearly 25 years, after starting his career in the School of Engineering at the University of Guelph in Ontario, Canada. Dr. Corsi is highly regarded as an educator. He has received numerous teaching awards, and in 2015 was inducted into the Academy of Distinguished Teachers, an honor held for the top 5% of teachers across UT Austin. He also received a Regents’ Outstanding Teaching Award for the entire UT system in 2016. Dr. Corsi’s research focuses on sources, physics and chemistry of indoor air pollution, particularly as related to pollutant interactions with indoor materials and innovative strategies for using such interactions to reduce human exposure to air pollution of both outdoor and indoor origin. He has served as principal investigator on over 70 projects, as major advisor to over 50 undergraduate and 70 graduate students, and as co-author on over 300 journal/conference papers, reports, and book chapters. His work has been featured in National Geographic, The Economist, Business Week, National Wildlife, Prevention, Men’s Health, National Public Radio’s Science Friday, Science Studio, the Academic Minute, the Canadian television series The Nature of Things, and more. Delphine Farmer, PhD Dr. Delphine Farmer is an Associate Professor in the Department of Chemistry at Colorado State

Fri, 22 Jun 2018 13:30:00 -0700


EPISODE507: Radio Joe & Bob Krell Report LIVE – IAQA Mid Atlantic Conference – Eva King, PhD & Wei Tang, PhD
This week on IAQradio+ and Healthy Indoors Magazine are coordinating on a live show from the IAQA Mid Atlantic Conference in Princeton, New Jersey. Today’s guests include Eva King, PhD and Wei Tang, PhD. Dr. Eva King, CIEC is the Principal Scientist and Founder of AURA EnviroScience. Eva received her Masters degree in Biochemistry from the University of Bielefeld, Germany, and her Doctorate from the University of Oxford, UK. Dr. Wei Tang is the founder, President and Laboratory Director of QLab in Metuchen, New Jersey. Dr. Eva King, CIEC is the Principal Scientist and Founder of AURA EnviroScience. Eva received her Masters degree in Biochemistry from the University of Bielefeld, Germany, and her Doctorate from the University of Oxford, UK. She has been involved in investigations and research into indoor environments and health, allergens, asthma and immunology for over 10 years, and has developed a wide range of new methods for exposure assessment. She has helped clients in different industry sectors, accelerating product development and validation, and assisted in clinical trials and other research studies. Her work has been published in many peer-reviewed scientific publications. Eva is an active member of the indoor air quality, industrial hygiene, and allergy research communities, and served on the Board of Directors of IAQA, and as Convention Committee Chair between 2013 and 2017. Dr. Wei Tang is the founder, President and Laboratory Director of QLab in Metuchen, New Jersey. Dr. Tang graduated from Cornell University with his Master and Ph.D. degrees in Soil Microbiology. He has conducted numerous research projects in Cornell University Soil Microbiology Laboratory in using microorganisms for bioremediation of environmental organic pollutants. His work in recent years has been focused on microbiological sampling and analysis methods for indoor environmental quality assessment. He has taught professional development courses and presented frequently at national conferences on analysis of indoor microorganisms and also on various topics including investigation and remediation of microbial growth in indoor environment. Dr. Tang is the inventor of several advanced microbial sampling devices including AccuScience Triple Gel-Tape, Sweep-Swab and Sponge-Swab. He also developed several advanced analytical methods such as AccuScience High Performance Spore Count and AccuScience Triplicate Analysis. Dr. Tang served on IAQA Board of Directors for three terms. H

Fri, 15 Jun 2018 13:15:00 -0700


EPISODE507: Radio Joe & Bob Krell Report LIVE – IAQA Mid Atlantic Conference – Eva King, PhD & Wei Tang, PhD
This week on IAQradio+ and Healthy Indoors Magazine are coordinating on a live show from the IAQA Mid Atlantic Conference in Princeton, New Jersey. Today’s guests include Eva King, PhD and Wei Tang, PhD. Dr. Eva King, CIEC is the Principal Scientist and Founder of AURA EnviroScience. Eva received her Masters degree in Biochemistry from the University of Bielefeld, Germany, and her Doctorate from the University of Oxford, UK. Dr. Wei Tang is the founder, President and Laboratory Director of QLab in Metuchen, New Jersey. Dr. Eva King, CIEC is the Principal Scientist and Founder of AURA EnviroScience. Eva received her Masters degree in Biochemistry from the University of Bielefeld, Germany, and her Doctorate from the University of Oxford, UK. She has been involved in investigations and research into indoor environments and health, allergens, asthma and immunology for over 10 years, and has developed a wide range of new methods for exposure assessment. She has helped clients in different industry sectors, accelerating product development and validation, and assisted in clinical trials and other research studies. Her work has been published in many peer-reviewed scientific publications. Eva is an active member of the indoor air quality, industrial hygiene, and allergy research communities, and served on the Board of Directors of IAQA, and as Convention Committee Chair between 2013 and 2017. Dr. Wei Tang is the founder, President and Laboratory Director of QLab in Metuchen, New Jersey. Dr. Tang graduated from Cornell University with his Master and Ph.D. degrees in Soil Microbiology. He has conducted numerous research projects in Cornell University Soil Microbiology Laboratory in using microorganisms for bioremediation of environmental organic pollutants. His work in recent years has been focused on microbiological sampling and analysis methods for indoor environmental quality assessment. He has taught professional development courses and presented frequently at national conferences on analysis of indoor microorganisms and also on various topics including investigation and remediation of microbial growth in indoor environment. Dr. Tang is the inventor of several advanced microbial sampling devices including AccuScience Triple Gel-Tape, Sweep-Swab and Sponge-Swab. He also developed several advanced analytical methods such as AccuScience High Performance Spore Count and AccuScience Triplicate Analysis. Dr. Tang served on IAQA Board of Directors for three terms. H

Fri, 15 Jun 2018 13:15:00 -0700


EPISODE506: Claudette Hanks Reichel, Ed.D – Building Science & Housing Resilience: Bringing Research to Practice
This week on IAQradio+ we welcome Dr. Claudette Hanks Reichel for a discussion on building science, LaHouse, resilience and bringing research to practice. Dr. Hanks Reichel is Professor and Extension Housing Specialist with Louisiana State University AgCenter. She serves as Director of LaHouse Resource Center, a public exhibit of multiple high performance housing solutions and hub of Extension education programs to advance resource-efficient, durable and healthy housing for the southern climate and natural hazards. Reichel has developed numerous educational outreach programs and resources relating to housing, including energy-efficiency, healthy homes, hurricane and flood resilience and others. She has authored more than 100 Extension publications, presented at numerous professional events, was twice a featured speaker at the National Building Museum in Washington DC, and has received 12 national and state level awards for program excellence and impact.

Fri, 08 Jun 2018 13:15:00 -0700


EPISODE505 - Ed Cross – “The Restoration Lawyer” – Restoration Industry Legal Issues & Answers
This week on IAQradio+ we welcome “The Restoration Lawyer” Ed Cross to discuss current legal issues and answers for restoration professionals. Mr. Cross has built a successful law practice that specially caters to the needs of insurance damage repair contractors and remediators. Mr. Cross received a Bachelor’s Degree in Speech Communications with an emphasis on Public Speaking from California State University at Northridge in 1986 (Dean’s Honor Roll), and his Juris Doctor Degree from Western State University in Fullerton California. Ed is also well known for his risk management advice, cleaning and restoration contracts and related forms available for free and/or for purchase on his website edcross.com . These are simple one page forms in plain English that protect payment rights and deter lawsuits. He has recently added contract forms specific to the needs of those doing work in Texas and Florida.

Fri, 25 May 2018 13:15:00 -0700


EPISODE505 - Ed Cross – “The Restoration Lawyer” – Restoration Industry Legal Issues & Answers
This week on IAQradio+ we welcome “The Restoration Lawyer” Ed Cross to discuss current legal issues and answers for restoration professionals. Mr. Cross has built a successful law practice that specially caters to the needs of insurance damage repair contractors and remediators. Mr. Cross received a Bachelor’s Degree in Speech Communications with an emphasis on Public Speaking from California State University at Northridge in 1986 (Dean’s Honor Roll), and his Juris Doctor Degree from Western State University in Fullerton California. Ed is also well known for his risk management advice, cleaning and restoration contracts and related forms available for free and/or for purchase on his website edcross.com . These are simple one page forms in plain English that protect payment rights and deter lawsuits. He has recently added contract forms specific to the needs of those doing work in Texas and Florida.

Fri, 25 May 2018 13:15:00 -0700


EPISODE504 - Joe Ledbetter & Andy McCabe – Who are the Restoration Rebels?
This week on IAQradio+ we welcome two of the founders of the Restoration Rebels. The disaster restoration industry is going through trying times and the rebels’ mission is to take back the industry that they love. We will talk about the reason the group was formed, the current state of the industry, and what the future looks like with Andy McCabe and Joe Ledbetter. Andy McCabe is a long-time restoration professional who lives in Bend, OR. He has written a book for mitigation contractors called The 24HR TECH, created an online training course by the same name, runs a podcast called The Claim Clinic and is President of the Alliance of Independent Restorers. Andy started his career in restoration, after brief stints as an electrician and financial advisor, with Dow Columbia restoration based in Portland, OR. Murray Dow Sr., the founder, was an original member and past president of both the NIRC and ASCR. Andy has worked his way up through just about every position in the industry. During that time he witnessed two former employers go bankrupt, and saw the rise of the TPA. After starting an Xactimate estimating service, Claims Delegates in 2012, he began to see some common problems that contractors deal with nearly every day. The two biggest problems were declining profits and increasing overhead. Everyone saw it, but it seemed no one was willing to do anything about it. So Andy decided to do something. Since the spring of 2017, he has run a free, contractor-focused Facebook group called the Restoration Rebels. Restoration contractors come to the group to solve problems and create solutions. Membership sits around 2,400 people as of the time of this writing. Andy is a vocal advocate for restoration contractors internationally. Joe Ledbetter is the Owner and Senior Business Consultant for DISASTERCO.COM(previously Clean Source Consulting) of Warren, MI. He is also President – Founder of Mannle Construction in Warren, MI. Prior to founding his current companies he was the Co-Founder/President of the Cleaning Connection of Warren, MI and the Director of Business Development of Drytech Group, in Ottawa, CA. In 2016 Joe surpassed 1 billion square feet of mitigation to commercial buildings and 1,000’s of residential losses ranging in size from $5,000.00 to $200,000.00. He is also one of the Restoration Rebel Leaders and his role is to help build and grow the group through sharing his knowledge and experience and helping develop the management and revenue opportunit

Fri, 18 May 2018 13:15:00 -0700
Follow Microshields IAQ News and Headlines Bloglines RSS Feed

Subscribe with Bloglines

 



IAQ News and Articles

Latest Top (10) News
http://recordings.talkshoe.com/rss1547.xml